OPERATION&MAINTENANCEMANUALTC670ERefrigerant Handling System4075 East Market StreetYork, PA [email protected] P/N 035-80756-
RTI Technologies, Inc.Page 9 0F R12 R134a30 42 4032 44 4234 46 4436 48 4638 50 4940 52 5142 54 5444 57 5646 59 5948 61 6150 64 6452 66 6754 69 7056
RTI Technologies, Inc.Page 10VACUUMIf the A/C System is "opened" for replacing components, it is important to draw a vacuum on thesystem bef
RTI Technologies, Inc.Page 11HOSE EVACUATIONIt's important that Air not be introduced into the A/C System during a Charging procedure. If a DeepV
RTI Technologies, Inc.Page 12CHARGE - HIGH SIDEFigure 5 Charge - High SideTo Charge Refrigerant, refer to Figure 5 and follow these steps:1. Perform
RTI Technologies, Inc.Page 13EXAMPLE: The level of liquid visible in the TC670E Charging Cylinder Sight Glass is 7.4 lbs.and the A/C system capacity i
RTI Technologies, Inc.Page 14SCHEDULED MAINTENANCEWEEKLY ...Check the oil level in the Compressor at least once a week. The Oil Level Sight Tube is vi
RTI Technologies, Inc.Page 15PROBLEMS & SOLUTIONSOn rare occasion the TC670E may seem to be performing differently or not at all. Experience hassh
RTI Technologies, Inc.Page 16PROBLEM: I turned a 30 lb. cylinder of new refrigerant up-side-down to pre-charge theCharging Cylinder with liquid. The C
RTI Technologies, Inc.Page 17
RTI Technologies, Inc.Page 18
TC670E CONVERTIBLE RECYCLING MACHINEThis Recycling Machine wasmanufactured by RTI in compliancewith all applicable UnderwritersLaboratories (UL) and
RTI Technologies, Inc.Page 19
TABLE OF CONTENTSTC670EStart-Up Instructions ... 3Safety Precautions ... 4Filling the Charging C
RTI Technologies, Inc.Page 3START-UP INSTRUCTIONS1) Check for any shipping damage. Place a claim with carrier if damage is discovered.2) Complete and
RTI Technologies, Inc.Page 4SAFETY PRECAUTIONS! Recover, Recycle, and Charge only the refrigerant for which the machine is configured.! Wear safety gl
RTI Technologies, Inc.Page 5LLLL CAUTION %Avoid breathing refrigerant or lubricant vapor or mist.Exposure may irritate eyes, nose and throat.If accide
RTI Technologies, Inc.Page 6FILLING THE CHARGING CYLINDERA/C Systems requiring service often do not have a full charge of refrigerant. To avoid unnece
RTI Technologies, Inc.Page 7RECOVER/RECYCLEFigure 2 Recover/RecycleTo Recover/Recycle, refer to Figure 2 and follow these steps:1. Attach Red and Blu
RTI Technologies, Inc.Page 8... NOTE ...As refrigerant is processed by the TC670E, temperature variations can cause vapor tochange to liquid which may
Commentaires sur ces manuels